Determination of the Planning Target Volume Margin by the Use of kv Portal Imaging and kvCone Beam Computerized Tomography Gözde Yazıcı, Mete Yeginer, Meltem Atamel, Pervin Hurmuz, Melis Gultekin, Mustafa Cengiz, Ferah Yıldız, Gökhan Özyiğit,

Yazar: Materyal türü: MakaleMakaleDil: İngilizce Yayın ayrıntıları:Akad Doktorlar Yayınevı, 2013.ISSN:
  • 1306-133X
Konu(lar): LOC sınıflandırması:
  • QZ200
İçindekiler: Uhod-Uluslararası Hematolojı-Onkolojı Dergısı 2013, Volume: 23, Issue: 4, Pages: 254-259 Özet: With portal imaging devices we can easily determine the position of bones in the patient, but we cannot visualize soft tissues. Kilo voltage cone beam computed tomography (CBCT) imaging integrated to treatment machine is relatively a new technique and provides higher resolution of soft tissues for imaging. In this study, our aim was to measure the differences between 2D-2D and 3D-3D registration based set-ups. We investigated whether using kV cone beam CT reduced setup errors compared to kV portal imaging. Four patients with the diagnosis of head and neck cancer (2 patients with cancer in the base of tongue, 2 with hypopharyngeal cancer) and 6 patients with prostate cancer were included in our study. The treatments were delivered with IMRT. kvCBCT-kv film comparisions were evaluated in 44 sets of data for head and neck cancer patients, and in 130 sets of data for prostate cancer patients. We analyzed the necessary planning target volume (PTV) margins for each group when only kv portal imaging is performed every day and found that a margin of 2.1 and 1.5 mm in all directions would be sufficient in case of pelvic tumors and head and neck cancers respectively if the lw portal images are performed every day. Compared to the literature the shifts were minimal when kvCBCT was performed after lw portal imaging. The immobilization procedures, followed strictly, may be reason for this observation.
Bu kütüphanenin etiketleri: Kütüphanedeki eser adı için etiket yok. Etiket eklemek için oturumu açın.
Yıldız derecelendirmeleri
    Ortalama puan: 0.0 (0 oy)
Mevcut
Materyal türü Geçerli Kütüphane Yer numarası Durum Barkod
Online Electronic Document NEU Grand Library Online electronic QZ200 .D48 2013 (Rafa gözat(Aşağıda açılır)) Ödünç verilmez EOL-933

With portal imaging devices we can easily determine the position of bones in the patient, but we cannot visualize soft tissues. Kilo voltage cone beam computed tomography (CBCT) imaging integrated to treatment machine is relatively a new technique and provides higher resolution of soft tissues for imaging. In this study, our aim was to measure the differences between 2D-2D and 3D-3D registration based set-ups. We investigated whether using kV cone beam CT reduced setup errors compared to kV portal imaging. Four patients with the diagnosis of head and neck cancer (2 patients with cancer in the base of tongue, 2 with hypopharyngeal cancer) and 6 patients with prostate cancer were included in our study. The treatments were delivered with IMRT. kvCBCT-kv film comparisions were evaluated in 44 sets of data for head and neck cancer patients, and in 130 sets of data for prostate cancer patients. We analyzed the necessary planning target volume (PTV) margins for each group when only kv portal imaging is performed every day and found that a margin of 2.1 and 1.5 mm in all directions would be sufficient in case of pelvic tumors and head and neck cancers respectively if the lw portal images are performed every day. Compared to the literature the shifts were minimal when kvCBCT was performed after lw portal imaging. The immobilization procedures, followed strictly, may be reason for this observation.