Yakın Doğu Üniversitesi
Büyük Kütüphane
Adres
Yakın Doğu Bulvarı, Lefkoşa, KKTC
İletişim
library@neu.edu.tr · +90 (392) 223 64 64
Google Jackets'tan alınan resim
OpenLibrary'den resim

The effects of different adhesive agents on the shear bond strength of a self-adhesive resin cement. Tolga Pekperdahci, Yuksel Turkoz, Oguz Ozan, Emre Seker.

Yazar: Materyal türü: MakaleMakaleDil: İngilizce Yayın ayrıntıları:2012. Wichtig Editore, Milan :ISSN:
  • 2280-8000
Konu(lar): LOC sınıflandırması:
  • QH505
Çevrimiçi kaynaklar: İçindekiler: Journal Of Applied Biomaterials & Functional Materials 2012, Vol 10 Issue, p149-156 Özet: Purpose: To compare the clinical success of a self-adhesive resin cement used in combination with different adhesive bonding systems with that of a conventional dual-cure resin cement.Methods: The study was performed with 136 freshly extracted molars embedded in acrylic resin blocks and 136 IPS e.max Press discs. Teeth and discs were randomly divided into four equal groups and cemented together using either RelyX ARC (ARC), RelyX Unicem (Unicem), RelyX Unicem+Adper-Prompt L-pop (L-pop), or RelyX and Unicem+Total-etch (Total-etch). Shear bond strength measurements were obtained before and after thermocycling. Following bond testing, the surfaces of one sample per subgroup (thermocycled and non-thermocycled), were assessed using scanning electron microscopy (SEM). Results: Among the non-thermocylced subgroups, ARC exhibited the highest bond strength values, followed by Total Etch, Unicem and L-pop. ARC also exhibited the highest bond strength values among the thermocycled subgroups, followed by Unicem, Total-etch, and L-pop. SEM analysis clearly revealed the negative effects of thermo-cycling on the mechanical properties of adhesive agents.Conclusions: RelyX Unicem may be preferable in many cases because of its simplified application and reduced technique-sensitivity.
Bu kütüphanenin etiketleri: Kütüphanedeki eser adı için etiket yok. Etiket eklemek için oturumu açın.
Yıldız derecelendirmeleri
    Ortalama puan: 0.0 (0 oy)
Mevcut
Materyal türü Geçerli Kütüphane Yer numarası Durum Barkod
Online Electronic Document NEU Grand Library Online electronic QH505 .T44 2012 (Rafa gözat(Aşağıda açılır)) Ödünç verilmez EOL-1395

Purpose: To compare the clinical success of a self-adhesive resin cement used in combination with different adhesive bonding systems with that of a conventional dual-cure resin cement.Methods: The study was performed with 136 freshly extracted molars embedded in acrylic resin blocks and 136 IPS e.max Press discs. Teeth and discs were randomly divided into four equal groups and cemented together using either RelyX ARC (ARC), RelyX Unicem (Unicem), RelyX Unicem+Adper-Prompt L-pop (L-pop), or RelyX and Unicem+Total-etch (Total-etch). Shear bond strength measurements were obtained before and after thermocycling. Following bond testing, the surfaces of one sample per subgroup (thermocycled and non-thermocycled), were assessed using scanning electron microscopy (SEM). Results: Among the non-thermocylced subgroups, ARC exhibited the highest bond strength values, followed by Total Etch, Unicem and L-pop. ARC also exhibited the highest bond strength values among the thermocycled subgroups, followed by Unicem, Total-etch, and L-pop. SEM analysis clearly revealed the negative effects of thermo-cycling on the mechanical properties of adhesive agents.Conclusions: RelyX Unicem may be preferable in many cases because of its simplified application and reduced technique-sensitivity.

Bu materyal hakkında henüz bir yorum yapılmamış.

bir yorum göndermek için.