Yakın Doğu Üniversitesi
Büyük Kütüphane
Adres
Yakın Doğu Bulvarı, Lefkoşa, KKTC
İletişim
library@neu.edu.tr · +90 (392) 223 64 64
Google Jackets'tan alınan resim
OpenLibrary'den resim

Air temperature effect on thermal models for ventilated dry-type transformers. Moonhee Lee, Hussein A. Abdullah, Jan C. Jofriet, Dhiru Patel, Murat Fahrioglu.

Yazar: Materyal türü: MakaleMakaleDil: İngilizce Yayın ayrıntıları:2011. Elsevier, Lausanne :ISSN:
  • 0378-7796
Konu(lar): LOC sınıflandırması:
  • TA153
Çevrimiçi kaynaklar: İçindekiler: Electric Power Systems Research MAR 2011, Vol 81 Issue 3, p783-789 Özet: The temperature of the air surrounding the windings of ventilated dry-type transformers is an important factor in the cooling of the windings since they are cooled only by the air. In particular, inner windings are sensitive to the air temperature in vertical cooling ducts. This study presents air temperature effect on the temperatures in foil-type inner winding for the dry-type transformers. A transformer rated at 2000 kVA was selected for the research and temperature distribution was calculated under constant and varying air temperatures inside vertical ducts at three different loads. The 2-D transient heat diffusion equation was solved using the finite element method by coupling it with the vector potential equation due to non-uniformly generated heat caused by eddy currents in the foil winding. The calculated temperatures at constant and varying air temperatures are presented together with experimental values. The numerical and experimental results of this study showed that the air temperature affects the accuracy of temperatures in foil-type inner winding greatly. (C) 2010 Elsevier B.V. All rights reserved.
Bu kütüphanenin etiketleri: Kütüphanedeki eser adı için etiket yok. Etiket eklemek için oturumu açın.
Yıldız derecelendirmeleri
    Ortalama puan: 0.0 (0 oy)
Mevcut
Materyal türü Geçerli Kütüphane Yer numarası Durum Barkod
Online Electronic Document NEU Grand Library Online electronic TA153 .A37 2011 (Rafa gözat(Aşağıda açılır)) Ödünç verilmez EOL-1640

The temperature of the air surrounding the windings of ventilated dry-type transformers is an important factor in the cooling of the windings since they are cooled only by the air. In particular, inner windings are sensitive to the air temperature in vertical cooling ducts. This study presents air temperature effect on the temperatures in foil-type inner winding for the dry-type transformers. A transformer rated at 2000 kVA was selected for the research and temperature distribution was calculated under constant and varying air temperatures inside vertical ducts at three different loads. The 2-D transient heat diffusion equation was solved using the finite element method by coupling it with the vector potential equation due to non-uniformly generated heat caused by eddy currents in the foil winding. The calculated temperatures at constant and varying air temperatures are presented together with experimental values. The numerical and experimental results of this study showed that the air temperature affects the accuracy of temperatures in foil-type inner winding greatly. (C) 2010 Elsevier B.V. All rights reserved.

Bu materyal hakkında henüz bir yorum yapılmamış.

bir yorum göndermek için.